Good performance, easy type, low noise inverter
Constant torque, variable torque mode (the power will increase one level in variable torque mode)
Flexible I/O terminals, online parameters setting, RS485 control, field bus control supply complete plan for customers.
Specifications:
VD4-4
|
011
|
Output
|
Matched motor(KW)
|
11
|
Rated output current(A)
|
25.0
|
Rated voltage(V)
|
AC380
|
Frequency range(Hz)
|
0~500
|
Frequency resolution(Hz)
|
0.01
|
Overload ability
|
150%Rated current for one minute,180%Rated current for one second
|
Input
|
Rated voltage/frequency
|
Three phases 380V,50/60 Hz
|
AC voltage permit fluctuate
range
|
Voltage:+20% voltage unbalance rate<3%
|
Frequency fluctuate range
|
Frequency:±5%
|
Power capacity
|
15
|
General specifications:
Main
Function
|
Modulation mod |
Space Optimized, voltage vector SVPWM modulation |
Frequency precision |
Digital Setting: max frequency×±0. 01%;
Analog Setting: max frequency×±0.2%
|
Frequency resolution |
Digital Setting:0.01Hz;
Analog Setting:max frequency×0.1%
|
Start frequency |
0.40Hz~20.00Hz |
Torque boost |
Auto torque boost,manual torque boost 0.1%~30.0% |
V/FFFFF curve |
Five modes:constant torque V/F curve, 1 V/F curve mode by user and 3 kinds of torque-derating modes (2nd power, 1.7th power, 1.2nd power) |
Accelerate/Decelerate curve |
Two modes:linear Acc/Dec, S curve Acc/Dec;seven kinds of Acc/Dec time (Maximum:6000 minutes) and unit(minute or second) is selectable. |
DC braking |
Initial frequency of DC braking:0~15.00Hz
Braking time:0~60.0 s
Braking current:0~80%
|
Power consumption braking |
Power consumption unit inside, can be connected with external braking resistor |
Jog |
Range of jog frequency:0.1Hz~50.00Hz, Acc/Dec time of jog operation 0.1~60.0s |
Internal PI |
Be able to form close loop control system easily |
Multi-step
speed running
|
Multi-step speed running can be realized by internal PLC or control terminals |
Textile wobble frequency |
Adjustable preset frequency and center frequency |
Auto voltage regulation
(AVR)
|
When the power system voltage changes, maintain the constant of output voltage |
Auto energy saving mode |
V/F curve is optimized automatically according to the load condition to realize energy saving operation |
Auto current limiting |
running current is limited automatically to avoid trip caused by over-current |
Fix-length control |
The frequency inverter will stop when reaching the fixed length |
Communication
function
|
With RS485 port, support Modbus-RTU protocol. Be with master-slave multi-devices linkage function |
Running function
|
Command mode |
Operated by three mode: digital panel, control terminal, serial port |
Frequency setting mode |
Setting modes can be selected ,including: potentiometer setting mode; & keys setting mode;digital function code setting mode; serial port setting mode;UP/DOWN terminal setting mode;analog voltage setting;analog current setting; pulse setting;combination setting; |
Digital input channel |
Forward/Reverse running command;6 channels programmable digital input,can set 35 kinds of function,X6 support 0~20KHz pulse output |
Analog input channel |
channel analog input ,4~20mA and 0~10V can be selected |
Analog output channel |
1 channel analog output,4~20mA、0~10V can be selected. |
digital output channel |
Programmable open-collector output,1 channel; relay output signal ,1 channel |
Digital panel |
LED Display |
indicate parameters: frequency ,output voltage, output current and so on. |
connected device display |
Indicate physical quantities, such as output frequency, output current ,output voltage and so on |
key Lock |
Lock all the keys |
Parameter Copy |
Copy function parameters between two inverters by remote control(developing) |
Protect function |
Over current protection;over voltage protection;under voltage protection;over heat protection;over load protection |
Option parts
|
extension cable of digital panel; brake resistor |
3. VB5 series
roduct description
|
VVVF/vector control, good performance, easy type, low noise inverter
Add PI tuning based on stable running, flexible I/O terminals, online parameters setting, fixed length control
Swing frequency control, RS485 control, field bus control supply complete plan for customers.
Specifications:
Type VB5-4_ _ _
|
5P5
|
7P5
|
Output |
Matched motor (KW) |
5.5
|
7.5
|
Rated output current (A) |
14.0
|
17.0
|
Rated voltage (V) |
AC 380
|
Frequency range (Hz) |
0~500
|
Frequency resolution (Hz) |
0.01
|
Overload ability |
150%Rated Current for 1 minutes,180% Rated Current for 1 second
|
Input |
Rated voltage and frequency |
three phases 380V; 50/60Hz
|
AC voltage permit fluctuate range |
Voltage: -20% ~ +20% voltage unbalance rate <3%
|
Frequency fluctuate Range |
Frequency: ±5%
|
Power capacity(KVA) |
8.5
|
11.0
|
General specifications:
Main
Function
|
Modulation mode |
Space Optimized, voltage vector SVPWM modulation |
Frequency precision |
Digital Setting: max frequency×±0. 01%;
Analog Setting: max frequency×±0.2%
|
Frequency resolution |
Digital Setting:0.01Hz;
Analog Setting:max frequency×0.1%
|
Start frequency |
0.40Hz~20.00Hz |
Torque boost |
Auto torque boost,manual torque boost 0.1%~30.0% |
V/FFFFF curve |
Five modes:constant torque V/F curve, 1 V/F curve mode by user and 3 kinds of torque-derating modes (2nd power, 1.7th power, 1.2nd power) |
Accelerate/Decelerate curve |
Two modes:linear Acc/Dec, S curve Acc/Dec;seven kinds of Acc/Dec time (Maximum:6000 minutes) and unit(minute or second) is selectable. |
DC braking |
Initial frequency of DC braking:0~15.00Hz
Braking time:0~60.0 s
Braking current:0~80%
|
Power consumption braking |
Power consumption unit inside, can be connected with external braking resistor |
Jog |
Range of jog frequency:0.1Hz~50.00Hz, Acc/Dec time of jog operation 0.1~60.0s |
Internal PI |
Be able to form close loop control system easily |
Multi-step
speed running
|
Multi-step speed running can be realized by internal PLC or control terminals |
Textile wobble frequency |
Adjustable preset frequency and center frequency |
Auto voltage regulation
(AVR)
|
When the power system voltage changes, maintain the constant of output voltage |
Auto energy saving mode |
V/F curve is optimized automatically according to the load condition to realize energy saving operation |
Auto current limiting |
running current is limited automatically to avoid trip caused by over-current |
Fix-length control |
The frequency inverter will stop when reaching the fixed length |
Communication
function
|
With RS485 port, support Modbus-RTU protocol. Be with master-slave multi-devices linkage function |
Running function
|
Command mode |
Operated by three mode: digital panel, control terminal, serial port |
Frequency setting mode |
Setting modes can be selected ,including: potentiometer setting mode; & keys setting mode;digital function code setting mode; serial port setting mode;UP/DOWN terminal setting mode;analog voltage setting;analog current setting; pulse setting;combination setting; |
Digital input channel |
Forward/Reverse running command;6 channels programmable digital input,can set 35 kinds of function,X6 support 0~20KHz pulse output |
Analog input channel |
1 channel analog input ,4~20mA and 0~10V can be selected |
Analog output channel |
1 channel analog output,4~20mA、0~10V can be selected. |
digital output channel |
1 channel programmable open-collector output, 1 channel relay output signal |
Digital panel |
LED Display |
indicate parameters: frequency ,output voltage, output current and so on. |
connected device display |
Indicate physical quantities, such as output frequency, output current ,output voltage and so on |
key Lock |
Lock all the keys |
Parameter Copy |
Copy function parameters between two inverters by remote control(developing) |
Protect function |
Over current protection;over voltage protection;under voltage protection;over heat protection;over load protection |
Option parts
|
extension cable of digital panel; brake resistor |
Note: please see inverter manual for correct details.
|
|
|